Skip to main content
Loading…
This section is included in your selections.

A. All new subdivisions shall be required to connect to the City water system. If an “auxiliary water supply” will also be used, back-flow prevention devices shall be installed to isolate the auxiliary supply from the City’s supply. Water service shall be brought to the property line of each lot being served. A minimum 15-foot-wide waterline easement is required for all public water facilities outside the public street right-of-way.

B. In the event there is inadequate pressure to serve the subdivision, the subdivider shall install those facilities required to ensure adequate pressure including, without limitation, pumps, water tanks, hydro-pneumatic tanks, etc., in accordance with the requirements of the City Engineer.

C. All water mains shall be no less than eight-inch diameter. The City Engineer may permit six-inch-diameter mains in areas where fire hydrants are not required and the water main will not be extended for future use.